An open draft pressure switch is responsible that results in the Honeywell water heater status light blinking 3 times.

Weak fan, faulty pressure switch, and blocked exhaust vents are the main culprits which lead your furnace draft pressure switch to stay open and get stuck.

honeywell water heater status light blinking 3 times

On top of that, a faulty gas valve along with clogged pipes also result in the Honeywell hot water heater status light blinking 3 times.

To ensure proper performance and solve the issue, it’s essential to solve the issues causing the problem. So, continue reading and we will talk about the reasons behind the issue along with their solutions. 

Table Of Contents

What Is A Pressure Switch And How Does It Work

The pressure switch on your Honeywell hot water heater works as a safety component. When the fan inside the Honeywell heater starts rotating, the pressure switch detects the activity. 

It closes the circuit to ensure the proper performance of the heater. However, if the pressure switch detects any abnormality, it keeps the circuit open, resulting in the heater blinking 3 times. 

Note: You can also read how to fix Honeywell hot water heater status light blinking 7 times.

Honeywell Water Heater Status Light Blinking 3 Times [Fixed]

Here, we will talk about all the reasons behind the Honeywell water heater flashing 3 times. So, let us dive deep into the details of the Honeywell issues and their solutions. 

1. Weak Fan

One of the major reasons behind the Honeywell water heater light blinking 3 times is due to the weak performance of the fan. This typically occurs when the motor is faulty or the blades are clogged.

weak fan

If the fan doesn’t work properly, then the pressure switch won’t be able to detect the signal. This will prevent the water heater from working and result in the light blinking 3 times. 

How To Fix It

Turn off the heater and examine the fan connected to the heater. Ensure that the fan is in proper working condition.

Repair or replace the motor if it’s faulty and clean the blades properly. Turn the heater back on and ensure that the issue is resolved. 

2. Faulty Pressure Switch

The faulty pressure switch is another common reason that causes the Honeywell hot water heater to blink 3 times.

faulty pressure switch 

If the pressure switch is malfunctioning, then the switch won’t work, preventing the circuit from closing. This will stop the heater from functioning properly and cause the light to blink 3 times. 

How To Fix It

Turn the water heater off and check the pressure switch properly. Identify the issue of the pressure switch.

Repair or replace the pressure switch and make sure that it’s installed properly. Turn the heater on and check whether the heater is working properly or not. 

3. Blocked Exhaust Vents

Oftentimes, the exhaust vents get blocked due to an accumulation of dirt, debris, and so on.

blocked exhaust vents

The air cannot pass properly through the vents due to the blockage which in turn causes the pressure switch to remain open. Thus, the Honeywell water heater blinks 3 times. 

How To Fix It

Turn off the water heater and let the temperature drop down properly. Check the exhaust vents of the heater and examine the dirt accumulation there.

Clean the vents properly and allow them to air dry. Turn on the water heater and ensure proper performance. 

4. Faulty Gas Valve

Another major reason behind the Honeywell status light blinking 3 times is the faulty gas valve.

faulty gas valve

When the gas valve connected to the water heater malfunctions, it prevents the gas from passing through the unit. This prevents the pressure switch from closing, thus, resulting in 3 times blinking of the hot water heater. 

How To Fix It

Turn off the heater and let it cool down completely. Turn off the gas valve and examine the valve properly. Repair or replace the gas valve with a new one and install it properly. Turn the gas valve on and ensure proper performance. 

5. Clogged Pipes

Air input and output of the water heater are important to ensure proper performance.

clogged pipes

Over time, dirt, debris, and so on accumulate in the pipes preventing the pressure switch from working properly. This results in the hot water heater blinking 3 times. 

How To Fix It

Turn the heater off and ensure that it’s cooled down completely. Examine the pipes properly and clean them.

Remove all traces of dirt from the pipes and dry them properly. Turn the heater back on and ensure that the lights are working properly. 

FAQs:

The Honeywell water heater blinks for various reasons. Depending on the flash numbers, it indicates proper performance or problems in the heater. 

How Do I Know That My Honeywell Water Heater Isn’t Working?

If the Honeywell water heater doesn’t work properly, then the water will come out cold or lukewarm. In some cases, the heater won’t turn on at all. 

Conclusion

Now you know how to identify the reasons behind your Honeywell hot water heater status light blinking 3 times and resolve the issue.

So, whenever you face your water heater blinking 3 times issue, take help from our guide and solve the problem by yourself.

However, if you have any more questions regarding your Honeywell hot water heater, leave a comment in the box below. We will get back to you soon with the solution. 

About David

David is a man who loves doing research and finding out the best solution to any type of heating appliance issues like heaters and fireplaces. Whenever he finds the perfect solutions to any issues of heating appliances after doing in-depth research, he loves to share them with his readers. In fact, his aim is to help his readers to fix the issues with their heating appliances easily.More about us .