If your garage heater is blowing cold air, shutting off early, or flashing mystery codes, you’re not alone. These units are tough, but they’re also picky—one bad sensor, a clogged vent, or a tripped limit can stop them dead.

In this Dyna-Glo electric heater troubleshooting guide, you’ll learn how to diagnose every major issue step-by-step, from no heat to stuck fans to error codes like EE, EF, LOC, and FA. By the end, you’ll know exactly what’s wrong and what to fix next. Let’s get started.
Dyna-Glo Electric Heater Troubleshooting [Solved A-Z]
Let’s look at the main reasons behind your Dyna-Glo electric heater not working properly and how we can fix each of them.
i) Heater Has Power But Not Generating Heat
This is one of those problems that can drive people crazy, because on the surface, the heater looks “alive” but refuses to actually do its job. Here’s a scenario of what the problem might actually look like:
- You flip the breaker on.
- The Dyna-Glo lights up.
- Maybe the fan runs.
- The display shows a temperature.
But the air coming out? Stone cold. The garage is still freezing, and you start wondering if the whole thing is junk.
I see this a lot with hardwired Dyna-Glo garage heaters like the EG7500 series, especially when there is an external thermostat or relay involved. From the outside, it feels like “the heater is dead.” In reality, what is dead is the path that sends power to the heating element.
In some garages, the heater is controlled by a basic wall thermostat that was never designed to handle 240V directly. So the installer runs the thermostat to a relay, and that relay switches the 240V feed to the heater.
If anything is miswired there, or if one leg of the 240V drops out, the unit can light up, and the fan may run, but the element will never actually heat. Other times, the heater itself is the problem.

I have seen heating elements that look fine on a meter and still fail under load. You get weird behavior like the top rod getting hot, the middle ones lukewarm, and the bottom rod staying cold. Technically, the element has continuity, but inside it is damaged and no longer delivering full output.
Then there are the safety devices that silently kill the heat while letting everything else look normal. An open high limit or safety switch can cut power to the element while the display and fan still operate. From your point of view, the heater “runs but doesn’t heat.”
Finally, in some cases, the issue sits on the control side. The thermostat sensor inside the unit can fail or come loose. On these Dyna Glo units, which usually show up as an “EE” code on the display.
When that happens, the control board no longer trusts the temperature reading and simply refuses to fire the element. Or the board itself stops sending power to the heating circuit while still powering the fan and display. So it looks alive, but the part that matters most is never energized.
So when a homeowner tells me “the unit has power but no heat,” I do not assume one single cause. I think in terms of a chain: power source, external controls, safeties, control board, and finally the heating element itself. Somewhere in that chain, something has dropped out.
Solution:
The way I approach this in the field is methodical. You do not fix this by guessing and throwing parts at the wall. You fix it by walking down the path the power takes until you find where it stops.
Step 1 – Check The Obvious Power And Settings
First, I make sure the basics are not embarrassing me. The breaker must be on, and it must actually be feeding 240V. That means I do not just look at the handle and assume.
I put a meter across the two hot legs and verify that I really have around 240 volts, not 120 on one leg and nothing on the other. If the unit has a display, I also check for any codes.
“LOC” means the heater is locked and will not respond to button presses until you unlock it by holding the power button for 10 seconds. “FA” means it is in fan-only mode, so of course it will blow cold air. If I see either of those, I fix them first before blaming hardware.
Step 2 – Inspect The Thermostat and Relay Setup
If an external thermostat and relay are driving the heater, that is my next suspect. I open the junction box or control box and check how the relay is wired. The coil should be on the thermostat side, usually low voltage or 120V, and the contacts should be switching the 240V feed cleanly.

I look for obvious signs of trouble like burned contacts, melted insulation, or a relay that clicks but does not actually pass power. If I suspect the thermostat or relay, I will temporarily bypass the external control and feed the heater directly for a test.
If it suddenly starts heating when bypassed, I know the problem is in the thermostat or relay circuit, not inside the heater.
Step 3 – Test Power At The Heating Element
Once I am confident that the unit should be calling for heat, I move inside the heater itself. With the cover removed and the heater calling for heat, I measure voltage directly across the Dyna Glo 7500 heating element terminals.
If I see around 240V at the element but the rods stay cold, the control side is doing its job, and the element has failed. At that point, the element is the suspect, whether or not it shows continuity on a simple resistance check. Under load, it is not doing what it should.
If I see zero volts at the element even though the unit thinks it is heating, then the problem is upstream: a limit switch, a sensor, a wiring break, or the control board.
Step 4 – Check High Limit & Safety Switches
Most of these heaters have one or more thermal safety limits in series with the element. Their job is simple: if the unit overheats, they open it and kill power to the heater.
With the power off, I set my meter to continuity and tested across each limit switch. If one is open when it should be closed, that is your no-heat condition right there. Some are resettable; many are not.
A non-resettable open limit needs to be replaced. The fan and display often still work because they are fed from a different branch, which is why the heater looks “on” while producing no heat.
Step 5 – Diagnose The Sensor & Control Board
If all the limits check out and there is still no power to the element, I turn my attention to the control board and the thermostat sensor. An “EE” code on the display tells me the sensor is either broken or disconnected. Without a valid sensor signal, the board will not energize the element.
I verify the sensor wiring is intact and properly plugged in. If the wiring is good and the code persists, then either the sensor itself is bad or the board’s input circuit has failed.
At that point, you are choosing between replacing the sensor, replacing the board, or replacing the entire heater, depending on what Dyna Glo actually sells for that model and what it costs.
Step 6 – Decide Whether To Repair Or Replace
This is the part most people skip in their heads. Let us say you have an older EG7500-type unit with a dead element and no available replacement part from the manufacturer. You can spend hours trying to retrofit something, or you can look at the price of a brand-new heater and be honest.
If the heater is fairly new and Dyna Glo can supply a replacement element, board, or limit at a reasonable price, repair makes sense. If the heater is several years old, parts are scarce, and you are paying a tech hourly to chase ghosts in a corroded box, replacement is often the smarter move.
Essentially, once you know exactly where the failure is, you do not just ask, “How do I fix this part? ” You also ask, “Is fixing this part still worth it? ”. At least, that is how I approach every no-heat Dyna-Glo garage heater that still has power but refuses to warm the room.
ii) Heating Element Shuts Off After First Cycle, But Fan Stays On
This one shows up a lot on the Dyna-Glo 7500-watt heaters. So, what exactly happens when you face this issue? The heater works perfectly the first time you turn it on. The element gets hot, the room starts warming up, and everything looks normal.

But as soon as that first heating cycle ends, the heater refuses to fire again.
The fan keeps running, the room keeps getting colder, and the element never comes back to life, no matter how low the temperature drops.
When a heater behaves like this, it usually means one thing: some part of the safety chain is cutting power to the heating element but not to the fan. The heater thinks it’s protecting itself, so it never “allows” the second heat cycle to start. Here are the most likely reasons:
i) High-Limit Switch Stuck Open
When the heater overheats even slightly, the high-limit switch opens to protect the unit. If that switch fails or gets weak, it may stay open after the first cycle. The heater will refuse to reheat because it “believes” it’s still too hot, so it keeps the fan running to cool itself indefinitely.
ii) Overheat Protection Triggered By Airflow Problems
If the intake or outlet is covered in dust, blocked by clutter, or positioned too close to a wall, the heater overheats during the first cycle. Once that happens, the system drops into a safety mode where only the fan runs.
iii) Thermostat Not Resetting
If the internal temperature sensor fails to accurately detect that the unit has cooled down, the heater won’t send the “reheat” signal to the element. Everything else looks normal, but the element never receives power again.
iv) Control Board Issue
If nothing else is wrong, the board may be failing to switch back to heating mode after the first cycle. This is exactly what happens when the board gets heat-stressed or develops a weak relay.
Solution:
To solve this particular problem, you need to go step-by-step. Here’s how I recommend you solve this problem:
i) Start With Airflow & Ventilation
Make sure the heater can breathe. Nothing should be blocking the front or the back. Clean off dust, remove boxes or objects stacked near it, and ensure it’s mounted with proper clearance. The heater will trigger a false overheat if air cannot move freely.
ii) Reset The Heater Completely
Turn off the breaker, not just the switch. Leave it powered off for at least 30 minutes. Let the heater cool down fully. Many overheat lockouts only reset once the unit returns to room temperature. After the cool-down, power it back up and test it again.

iii) Check The High-Limit Switch
The high-limit switch should read closed when the heater is cool.
Use a multimeter on the switch after the heater completes its first cycle:
- If it’s open and never resets, the switch is bad.
- If it’s a non-resettable type, it must be replaced.
- If it resets normally but trips again too soon, the heater is overheating – go back to airflow, dust buildup, and positioning.
iv) Check The Display For Any Signs of Overheating (EF)
If “EF” shows up, the unit is telling you exactly what went wrong: it overheated.
Clear obstructions, clean the inlets and outlets, and repeat the cool-down reset. If EF returns immediately after the first cycle, the limit switch or sensor is tripping too easily.
v) Replacing The Control Board
If you’ve fixed all the above, then the only logical conclusion is that the board is failing internally. You can order boards and sensors directly from Dyna-Glo. If the heater is older and the parts cost too much, replacing the whole unit may be smarter.
iii) Heating Element Works, But Fan Won’t Spin
When you walk into the garage and see the heating element glowing red while the fan sits completely still, that’s a failure you never ignore. The heater is basically cooking itself alive.
The room feels hotter than it should, the unit is radiating heat like a furnace, and the element only gets brighter because nothing is pushing air across it to cool it down.
The moment you see this, the pattern is obvious: the heater is still producing heat, but absolutely nothing is moving that heat away. That’s not a minor performance issue—that’s a safety problem.
There are a handful of reasons this happens. Sometimes the fan motor has failed entirely. The heater keeps sending power to the element, but the fan motor never responds, so the heat just builds and builds.
Other times, the problem is the start/run capacitor. Some of these motors rely on a capacitor to get spinning, and when it dies, the motor either hums or does nothing at all while the heating element keeps cooking.
You can also run into a simple mechanical obstruction. Dust buildup, a bent shroud, debris sucked into the blades, or even a chunk of insulation can jam the fan and stop it from turning.
And then, there’s always the control board issue: the board may be powering the heating element but never sending voltage to the fan, leaving it dead even though the heater is running.
Regardless of which one it is, the outcome is always the same: a red-hot heating element with zero airflow, extreme overheating, and a very real fire risk.
Solution:
The moment you see the heating element glowing red while the fan refuses to spin, the very first step is to shut the heater down immediately. Cut power at the breaker or unplug it—don’t wait to “see if it fixes itself.” Running a heater in this condition can permanently damage the unit or start a fire.
Once it’s safely powered off, check for anything physically blocking the fan. Try spinning the blades by hand.
If they don’t move freely, look for whatever’s jamming them: dust buildup, debris, a bent shroud, or even ice in colder garages. Clear the obstruction and make sure the fan turns smoothly before you move on.
If the fan spins freely by hand, the next step is figuring out whether the motor is actually getting power. When the motor receives voltage but doesn’t move, the problem usually comes down to a failed motor or a bad capacitor.
If the motor gets no voltage at all, the issue is likely in the wiring or the control board not sending power where it should. Look up your Dyna Glo 7500-watt heater wiring online if you’re having issues with it.
For anyone comfortable with a multimeter, you can test the capacitor in capacitance mode and check the motor windings for continuity. Any major imbalance or an open circuit is a clear sign that the part is done.
In most cases, replacing the motor and capacitor together is the most reliable fix since one tends to fail soon after the other. But it also depends on whether you can find the right Dyna-Glo electric heater parts. Generally, when it comes to the fan components, you should be able to find them.
Before deciding to repair it, look closely for signs of overheating. A heater that’s been running with a glowing red element and no airflow may have deeper damage inside. Check for melted wire insulation, discolored wiring, warped plastic, or a burnt smell in the housing.
If any of that shows up, replacing the unit may be smarter than sinking money into parts. Severe overheating shortens the lifespan of every component inside, and once the damage spreads, it’s rarely worth trying to save the heater.
iv) Heating Won’t Blow Heat & Doesn’t Respond
This is also one of the most common Dyna-Glo heater problems you’ll face. It’s hard to diagnose because the heater appears alive but refuses to actually run. I’ll explain what happened to a client of mine.
The display usually froze at something like 66°F, and when he tried to start the heater, the number jumped briefly to something like 77°F before the unit immediately shut itself down.
No fan, no heat, no airflow. Even the temperature buttons stop behaving normally, either not responding at all or changing settings inconsistently. This kind of failure usually points toward something that disables both the heating element and the fan at the same time.
A failing control board is at the top of the list because when the board can’t correctly read the thermostat, process button inputs, or send power to the motor, the heater basically becomes a frozen display screen.
A limit switch stuck open can cause the same symptom by cutting power to the element and the fan while leaving the display powered.
Lock mode (“LOC”) can also cause the illusion of a dead heater by blocking all functions until it’s unlocked. And if the thermostat sensor fails (“EE”), the board refuses to start the heater at all because it thinks the temperature reading is unsafe or invalid.
Solution:
Start with the simplest checks. If you see “LOC” anywhere on the screen, hold the POWER button for about ten seconds to unlock the controls.
If the display says “FA,” switch the mode back to “AUT” so the heater can run in heating mode. After that, check for error codes. An “EE” code almost always means the thermostat sensor has failed. The heater won’t run again until the sensor—or the board it’s connected to—is replaced.
If replacing the thermostat works, that’s great—you’ve just fixed the problem. Otherwise, you need to keep on diagnosing. So, you’d have to move on to the limit switch if the problem still isn’t solved.
A limit switch stuck open will block power to the fan and the heating element, leaving only the display lit. If the limit doesn’t reconnect after the heater cools down, it needs to be replaced.
But if airflow is fine, the limit switch checks out, and the buttons still don’t respond properly, the control board becomes the main suspect. A failing board won’t allow the heater to properly switch modes, read temperatures, or energize components. At that point, the next step is to jot down your model and serial number and call Dyna-Glo for the correct replacement board.
And since these units usually come with only a one-year warranty, anything older than that is outside coverage.
If you’re uncomfortable testing live power or control circuits, calling an HVAC technician is usually the safer move—especially if the board is failing, because that repair is rarely plug-and-play for beginners.
v) Not Heating At All
When the heater refuses to warm up, it’s easy to assume something major has failed. But before looking at error codes or internal components, there are two simple non-error-code issues that can stop the heater from producing heat.
First, the heater won’t turn on the element if the room temperature has already reached the thermostat’s set temperature. If the setpoint is too low, the heater simply has no reason to activate. This is one of the most common oversights.
Second, the breaker may have tripped. These garage heaters draw a fair amount of current, and a partially tripped breaker can leave the display running while cutting power to the heating element.

Both situations create the illusion of a dead heater even though nothing is mechanically wrong. Once these basics are ruled out, the next step is to look at Dyna-Glo electric heater troubleshooting codes to figure out what’s wrong.
Each code points to a specific fault that prevents the unit from heating. Here are the most common error codes you should be on the lookout for:
i) Display Shows “”EE”—Thermostat Sensor Fault
“EE” means the control board cannot read the room temperature. When the sensor signal is compromised, the board shuts down heating entirely, as it doesn’t know if the heater is operating within safe limits. This can cause erratic behavior, dead heat cycles, or a heater that won’t start at all.
ii) Display Shows “”EF”—Overheat Protection
“EF” means the heater believes it has overheated. This is almost always caused by restricted airflow—blocked intake grilles, a dusty heater, or objects placed too close to the front or back of the unit.
When the heater can’t move air properly, internal temperatures spike, and the safety circuit cuts the heat while keeping the fan running to cool the unit down. It often mimics the symptom of “fan only, no heat.”
iii) Display Shows “LOC”—Heater in Lock Mode
“LOC” is simply lock mode. It disables the front panel buttons to prevent accidental changes. The heater may appear frozen or unresponsive when this is active, but the unit is not malfunctioning—it’s just locked.
iv) Display Shows “FA” And Only Blows Cold Air
“FA” stands for fan-only mode. The heater is intentionally blowing cool air and will not engage the heating element in this mode. It’s not a fault—just the wrong setting for heating.
Solution:
Start by checking the basics. Make sure the thermostat setpoint is higher than the current room temperature. If the heater thinks the room is already warm enough, it will never turn on the element.
Then head to the breaker panel and make sure the breaker is fully reset. If the breaker is even slightly tripped, the display may light up while the heating components remain dead. Reset the breaker fully and try the heater again. Once those two quick checks are done, move on to the error-code-specific fixes.
i) Fixing “EE” Error Code
Begin with a visual inspection of the thermostat sensor wiring. Look for loose connectors, pinched wires, or any visible damage. A bad plug connection is all it takes to trigger an EE code. If the wiring is intact, the next step is replacing the thermostat sensor itself.
In some cases, the control board may also need replacement if it fails to read a working sensor. When you’re unsure whether the sensor or the board is at fault, it’s best to contact Dyna-Glo support with your model and serial number or bring in a local HVAC technician who can test the components directly.
ii) Fixing “EF” Error Code
Clear all obstructions from the front and rear of the heater. Make sure nothing is stacked near it. Dust the grilles thoroughly and clean any visible debris. After clearing the airflow, turn the breaker off and let the heater cool for at least 30 minutes. This allows the internal limit switch and sensors to reset.
If the EF code returns shortly after restarting, the heater is still overheating, and you’ll need to inspect the high-limit switch, airflow path, and dust accumulation more deeply.
iii) Fixing “LOC” Code
Hold the POWER button for about ten seconds to unlock the controls. If the heater is in a shared garage or around kids or pets, consider re-enabling lock mode once the settings are configured.
iv) Fixing “FA” Code
Switch from “FA” to “AUT” (or whatever heat mode your model uses). After switching modes, confirm that the thermostat setpoint is higher than the room temperature so the heater has permission to activate the element.
v) The Heating Element Has A Burning Smell
A burning smell from a Dyna Glo heater can mean two completely different things, and knowing which one you’re dealing with makes all the difference.
Let’s look at the first scenario. With a newer unit or one that’s been sitting unused for months, you’re simply smelling dust or a thin layer of factory oil burning off the heating coils. This is normal. Every electric heater does this the first time it’s run, and the smell usually fades after a short period of use.
But the second possibility is the one you take seriously: a genuine fire hazard. If combustible items are within three feet of the heater, the radiant heat can scorch them.
If the heater is mounted too low, too close to a wall, or too tight against a ceiling, the trapped heat can leave surfaces discolored or even start to char debris caught behind the unit.
Dyna-Glo is strict about this for a reason—the heater must be mounted at least eight feet off the floor and installed with proper clearances on all sides.
When the smell is coming from something other than dust burn-off, you’ll usually find the clues nearby: a melted surface, a singed object, or an overheated wall section.
Solution:
Start by figuring out whether the smell is just normal burn-off. Run the heater in a well-ventilated garage with fresh airflow.
A “new heater smell” should noticeably fade the longer it runs and usually disappears after a few hours of operation. If the smell weakens over time, that’s a good sign that it was simply factory residue or long-settled dust cooking off the coils.
Next, verify all clearances around the heater. Make sure there’s at least three feet (0.9 m) of empty space between the heater and anything flammable.
The unit must also be mounted at least eight feet above the floor. If the heater isn’t installed with proper clearances, heat can build up behind it and cause scorching—even if nothing directly touches the unit.
After confirming proper clearance, inspect the surrounding area closely. Look for any signs of actual heat damage: discolored drywall, melted plastic, darkened surfaces, or any charred dust or debris stuck to the heater housing.
If you see any of these warning signs, shut the heater down immediately and correct the installation or relocate the unit to a safer position.
Finally, know when to stop using the heater altogether. If the burning smell persists even after proper break-in time, or if you repeatedly trigger EF/overheat behavior during normal operation, something is overheating.
At that point, it’s safer to shut the heater down and inspect it thoroughly. The other option is to stop using it entirely before risking damage to the garage, you, or the unit itself.
vi) Won’t Stop Working Even After Being Shut Down
It’s common to think something is wrong when you press OFF and the heater refuses to shut down immediately. The display goes dark, the heat stops, but the fan keeps spinning. Sometimes it runs steadily, and other times it cycles on and off a few times before finally stopping.
This behavior looks suspicious if you’re expecting the heater to shut down the moment you press the button. But the reality is that this isn’t a malfunction at all. It’s the heater’s built-in cool-down cycle, designed to protect the heating element from thermal stress.
Inside the heater, a temperature sensor monitors the internal heat level. Even after you turn the heater off, the components remain extremely hot, especially the heating element.
If the fan were to shut off instantly, that trapped heat would sit inside the chamber and shorten the life of the element or even damage nearby wiring.
To prevent that, the heater runs the fan until internal temperatures drop to a safe level. Here is an example of how the cycle behaves:
- If the heater was running for 15 seconds or less, the cool-down may last around 10 seconds.
- If it ran for more than 15 seconds, the fan may cool for 90 seconds or longer.
- Depending on the garage temperature, the full cool-down can take 5 to 10 minutes, sometimes cycling on and off several times before the heater fully shuts down.
In other words, the fan staying on after shutdown isn’t a glitch—it’s the heater protecting itself. But the main problem is only if it runs endlessly. In that case, it’s either a problem with the fan or the control board.
Solution:
First, know that this fan behavior is completely normal as long as the heater eventually stops. The temperature sensor tells the fan exactly when to shut off, and the heater follows a programmed sequence depending on how hot the internal components are.
If your fan stays on for a couple of minutes or cycles on and off a few times, that’s exactly what the manual describes. Just give it time to cool the heater safely. However, if the fan keeps running endlessly with no heat, no error codes, and no sign of shutting down, that points to a problem.
The most common causes are a stuck relay or a control board issue, where the board doesn’t release the fan circuit even after the cool-down is complete.
But you already know how to deal with those problems, as we discussed them at length earlier. Now, all you have to do is implement the right solution, and the problem should be solved.
How to Maintain a Dyna-Glo Electric Heater to Prevent These Issues
Keeping your garage heater healthy isn’t complicated, but ignoring basic upkeep is the fastest way to end up with overheating issues, sensor failures, endless fan cycles, and weak heat output.

A little routine care goes a long way toward preventing the exact problems covered in this guide.
i) Keep the Heater Clean
Always shut off the power at the breaker and let the heater cool completely before touching it. Once it’s fully cooled, wipe the exterior with a simple dry duster every so often to keep buildup from creeping into the air inlets.
During the off-season, when the unit is cold and sitting unused, you can wipe it down with a lightly damp cloth to remove settled dust. Skip harsh cleaners, polishes, metal scrub pads, or anything abrasive, as they damage the finish and can push debris into crevices where you don’t want it.
ii) Protect The Heating Element And Sensors
Dust is the number one enemy of electric heaters. It burns, it triggers false overheat signals, and it suffocates airflow. Make it a habit to check the intake and outlet vents and remove any visible dust or cobwebs.
A clean airflow path reduces the chance of tripping the EF overheat protection or overheating the limit switch.
iii) Store the Heater Properly in the Off-Season
If the heater will sit unused for months, disconnect the power supply at the breaker. Store it in a cool, dry place where moisture won’t collect around the wiring or heating element.
Moisture and corrosion are silent killers of sensors and connectors, and most “mystery problems” that show up in winter start during summer storage.
iv) Preserve Mechanical Components
The motor in these units is permanently lubricated, so you never need to oil it—but you do need to keep dust off it. A clean motor breathes better, runs cooler, and puts less strain on the control board.
While you’re cleaning, give the fan blades a quick visual check to make sure nothing is stuck, bent, or rubbing against the shroud.
v) Know When to Call a Technician
Anything deeper than basic cleaning, such as replacing sensors, diagnosing a board failure, or testing electrical components, should be handled by someone qualified. These heaters run on 240 volts, and guessing your way through repairs can turn a simple issue into a dangerous one.
If you’re unsure, get help instead of forcing a fix. Regular cleaning, proper spacing, and smart off-season storage prevent the bulk of heating failures long before they happen. A few minutes of care now saves hours of troubleshooting later and keeps your heater reliable when you actually need it.
FAQs:
Why does my Dyna Glo heater click but not start heating?
A clicking sound usually means the control board is trying to activate the element, but a safety switch or sensor isn’t allowing it. Check airflow, high-limit switches, and thermostat settings first before suspecting the board.
Can a weak breaker cause random shutdowns or no heat?
Yes. A weak or partially tripped breaker can keep the display alive while starving the element of power. Always reset the breaker fully and verify 240V across both legs.
Why does my heater smell slightly metallic sometimes?
A faint metallic smell usually comes from hot dust or the element heating rapidly after long inactivity. If it fades quickly, it’s normal. If it worsens, check for overheating or blocked airflow.
Can cold garage temperatures affect how the heater behaves?
Extremely cold garages can stress components, slow the fan motor, and make sensors react unpredictably. Clear any ice near the fan, and let the heater warm up gradually.
How often should I clean inside the heater?
A light dust cleaning every few months is enough for most garages. If you run woodworking tools or anything that kicks up debris, clean it more often to prevent false overheat trips.
Conclusion:
You’ve now walked through every major issue that can stop one of these units from heating or other problems, all the way up to failing control boards. With a methodical approach, fixing a Dyna Glo electric heater troubleshooting problem is usually straightforward.
Just clear the airflow and test each safety in order. Keep the heater clean, give it proper clearance, and store it dry in the off-season, and most of these failures never come back. If you also own a kerosene model, check out my full troubleshooting guide on Dyna-Glo kerosene heaters.